| Cords
for butt sets and test sets. |
| Below,
click view to check out a photo and additional
information on that product. |
| Aines
Number |
Telco
Number |
Picture
Y/N |
Description |
| CS-1 |
H2B
(old) |
No |
6A
clips & vinyl tube for butt sets |
| CS-2 |
* |
Yes
View |
Plug
& resistor for butt sets |
| CS-2.1 |
* |
No |
Resistor
to 6P clips |
| CS-2.1A |
* |
No |
Resistor
to 6P clips |
| CS-2.2 |
W2CL |
No |
Resistor
to spades |
| CS-3GS |
* |
Yes
View |
Ground
start cord |
| CS-3.0 |
* |
No |
Ground
start w/o plug and jack |
| CS-3.1 |
* |
No |
Ground
start w/o plug and green lead |
| CS-3.2 |
* |
Yes
View |
Ground
start green lead and plug |
| CS-3.3 |
* |
No |
Ground
start w/o plug & jack w 60U clips |
| CS-4 |
* |
No |
6P
clips and vinyl tube |
| CS-5 |
H2C |
Yes
View |
346
type plug |
| CS-5.1 |
H2C
(modified) |
No |
CS-5
modified for Chesilvale |
| CS-6 |
* |
Yes
View |
Telepath
test set cord, 4 leads |
| CS-6A |
* |
No |
Telepath
# 834035 |
| CS-6.1 |
* |
No |
Telepath
cord for 505 set with 60U clips |
| CS-6.2 |
* |
No |
Telepath
cord for 505 set with 6A clips |
| CS-6.3 |
* |
No |
Telepath
cord for 525-2 set with 6A clips |
| CS-6.4 |
* |
No |
Telepath
cord for 505 set with 6P clips |
| CS-6.4A |
MT-911 |
No |
Metro
Tel 911 butt set cord with 6P clips |
| CS-6.4A1 |
MT-911 |
No |
Same
as CS-6.4A, but with 6 foot cord |
| CS-6.5 |
* |
No |
Telepath
cord for 570-3 set with 6A clips |
| CS-7 |
H2B |
Yes
View |
Butt
set cord with 6A clips and overbraid |
| CS-7.1 |
W2BT4 |
Yes
View |
Same
as CS-7 with no spade lock |
| CS-8 |
H2B |
Yes
View |
Butt
set cord with 6P clips and overbraid |
| CS-8.1 |
TS-22 |
Yes
View |
For
Harris TS-22 type butt sets |
| CS-8.2 |
* |
No |
For
Chesilvale butt set |
| CS-8.2A |
* |
No |
CS-8.2
with no spike on clip |
| CS-8.3 |
* |
No |
CS-8
with 54 inch overbraid (BECO) |
| CS-8.3A |
* |
No |
CS-8.3
with no clips or boots |
| CS-9 |
* |
Yes
View |
Test
set cord for NUTMEG Utilities |
| CS-10 |
* |
No |
Cord
for D&B Power |
| CS-11 |
* |
No |
14foot
- 4 pair modular mounting cord |
| CS-12 |
* |
Yes
View |
Butt
set cord overbraid, no clips |
| CS-13 |
KS-8455 |
No |
For
Metro Tel and WECO 8455 type sets, 6A clips |
| CS-13.1 |
KS-8455 |
No |
CS-13
overbraided |
| CS-14 |
KS-8455 |
Yes
View |
For
Metro Tel and WECO 8455 type sets, 6P clips |
| CS-14.1 |
KS-8455 |
No |
CS-14
overbraided |
| CS-15 |
* |
Yes
View |
471A
jack to 6A clips |
| CS-16 |
* |
Yes
View |
471A
jack to 6P clips |
| CS-16.1 |
* |
No |
471A
jack to 6P clips and modular plug |
| CS-16.1A |
* |
No |
471A
jack to Mueller #30 & modular plug |
| CS-16.2 |
* |
No |
Same
as CS-16, 4 foot long |
| CS-16.3 |
* |
No |
Same
as CS-16, 6 foot long |
| CS-17 |
W1AP |
Yes
View |
Jumper
lead for Telco |
| CS-18 |
* |
Yes
View |
471A
jack to 176A plug, 3 foot |
| CS-18.1 |
2W38A |
No |
471A
jack to 176A plug, 5 foot |
| CS-19 |
* |
No |
471A
jack to universal modular plug |
| CS-20 |
* |
No |
Test
lead, 176A plug to 6A clips |
| CS-21 |
* |
No |
Test
lead, M642 plug to 6A clips |
| CS-22 |
2W37A |
Yes
View |
471A
jack to Popper 6780 clips |
| CS-22.1 |
* |
No |
471A
jack to Mueller 30 clips |
| CS-23 |
W2DB4 |
Yes
View |
Butt
set cord, Popper 6780 clips & overbraid |
| CS-24 |
2W41A |
Yes
View |
471A
jack to 360 spring chucks |
| CS-24.1 |
W2CJ |
No |
CS-24
w/o 360 chucks or 471A jack |
| CS-25 |
1W13A |
Yes
View |
3
foot red lead, 360A chuck each end |
| CS-25.1 |
1W13B |
No |
6
foot red lead, 360A chuck each end |
| CS-26 |
W1AH |
Yes
View |
6
foot black test lead, copper strand with
6P clip |
| CS-27 |
* |
No |
3
foot data test lead for TAG Inc. with 6A
clip |
| CS-28 |
* |
No |
3
foot data test lead for TAG Inc. with 6P
clip |
| CS-29 |
* |
Yes
View |
Test
cord for Triplett Transmission test set |
| CS-30 |
MT-811 |
No |
Butt
set cord for Metro Tel 811 |
| CS-31A |
140A |
No |
For
Aines 140A Tone generator set, Mueller clips |
| CS-31B |
140B |
No |
For
Aines 140B Tone generator set, Mueller clips |
| CS-31.1A |
140A |
No |
For
Aines 140A Tone generator set with 6P clips |
| CS-31.1B |
140B |
No |
For
Aines 140B Tone generator set with 6P clips |
| CS-32 |
240 |
No |
For
Aines 240 Tone generator set, Mueller clips |
| CS-32.1 |
240 |
No |
For
Aines 240 Tone generator set, with 6P clips |
| CS-33 |
|
No |
Butt
Set cord, modular plug & 6P clips |
| CS-33.1 |
|
No |
Butt
Set cord, modular plug & 6A clips |
| CS-33.2 |
|
No |
Butt
Set cord, modular plug & 60Us |
| CS-34 |
W2CK |
No |
Forms
part of CS-18 cord, 3 foot |
| CS-34.1 |
W2CK |
No |
Forms
part of CS-18 cord, 10 foot |
| CS-35 |
Biddle |
Yes
View |
Test
set cord for Biddle, 3 foot |
| CS-35A |
|
No |
Double Banana to 471 |
| CS-35.1 |
Biddle |
No |
Test
cord for Biddle, 10 foot |
| CS-36 |
|
Yes
View |
Butt
set cord with 6P clips & modular JACK |
| CS-37 |
BTC
3046-7 |
No |
Caller
ID cord, Mueller clips |
| CS-37A |
BTC
3046-7 |
No |
Caller
ID cord, 60U clips |
| CS-37.1 |
BTC
3046-7 |
No |
Caller
ID cord, 6P clips |
| CS-37.1A |
HB |
No |
For
Hosiden Besson butt set |
| CS-37.2 |
Walker |
No |
For
Walker butt set, no clips |
| CS-38 |
W2BJ |
No |
Test
lead, W2BJ |
| CS-39 |
W1BU |
No |
25
foot coil ground cord, W1BU |
| CS-40 |
|
No |
8
foot, 8 conductor cord with RJ45 at each
end |
| CS-41 |
|
No |
13
inch test leads with 6Ps and boots |
| CS-42 |
M4AR |
No |
5
foot, 3/4 inch patch cord, modular to spades |
| CS-43 |
AT-7781 |
No |
AT-7781
B Temporary Bond |
| CS-44 |
Melard |
No |
Modular
plug to modular plug & 6P clips |
| CS-45 |
2W17A |
No |
267
plug to 360 spring chucks |
| CS-46 |
W2HF |
No |
M642
plug to 6780 clips, 10 foot |
| CS-46.1 |
|
No |
M642
plug to 60U clips, 15 foot |
| CS-47 |
|
No |
3 conductor, 8 position modular plug to
6P clips |
| CS-47.1 |
|
No |
2
conductor, 8 position modular plug to 6P
clips |
| CS-48 |
Tectronics |
No |
ISDN
Test Set cord |
| CS-49W |
|
No |
White
test lead, 18 inch with 60U clips |
| CS-49Y |
|
No |
Yellow
test lead, 18 inch with 60U clips |
| CS-50W |
|
No |
100
ohm test lead, 18 inch with 60U clips |
| CS-50Y |
|
No |
300
ohm test lead, 18 inch with 60U clips |
| CS-50G |
|
No |
600
ohm test lead, 18 inch with 60U clips |
| CS-50BK |
|
No |
900
ohm test lead, 18 inch with 60U clips |
| CS-50R |
|
No |
1000
ohm test lead, 18 inch with 60U clips |
| CS-51 |
HD
TELCOM |
No |
Mexican
Model |
| CS-52 |
W1U |
No |
Telco |
| CS-53 |
M4AR |
No |
Telco |
| CS-54 |
M4AU |
No |
Telco |
| CS-55 |
M8P |
No |
Telco |
| CS-56 |
P2EF |
No |
Telco |
| CS-57 |
|
No |
8
foot, 8 conductor cord with RJ45 for DS-1
tests |
| CS-58 |
|
No |
Rubber
test leads, banana to 360 plug |
| CS-61 |
P2EF |
Yes
View |
P2EF
Plug on each end. 6 foot. For COOK 303 and
3800 Series MDF blocks |
| CS-62 |
P2EF |
No |
6
foot cord, P2EF plug one end, 6P clips other
end |
| CS-63 |
P2EF |
No |
Metro
Tel 911 Butt Set, Mini-mod to P2EF plug,
6 foot |
| xxx |
P2EF |
No |
P2EF
plug can be assembled for any butt set...call
for quote |
| PC-01 |
|
No |
Single
Bantam Shielded Cord, 20 foot (Belden
8420 wire) |
| PC-02 |
|
No |
Single
Bantam Shielded Cord, 15 foot |
| PC-03 |
|
No |
Single
Bantam Shielded Cord, 6 foot |
| PC-04 |
|
No |
Double
Bantam Shielded Cord, 30 foot |
| PC-05 |
|
No |
Double
Bantam Shielded Cord, 12 foot |
| PC-06 |
|
No |
Single
Bantam Shielded Cord, 10 foot |
| PC-07 |
|
No |
Single
Bantam Shielded Cord, 12 foot |
| PC-08 |
|
No |
Single
Bantam Shielded Cord, 30 foot |
| PC-09 |
400210A |
No |
Cord,
T-1 Test, 260-508-460 (10 foot bantam, 60U
clips) |
| PC-10 |
2W6A |
No |
Switchcraft
267 plug to 60U clips |
| PC-11 |
3P6A |
No |
3
conductor tinsel 267 plug each end, 1 foot |
| PC-12 |
3P7A |
No |
Same
as PC-11, 6 foot |
| PC-13 |
3P6F |
No |
Same
as PC-11, 10 foot |
| PC-14 |
|
No |
Same
as PC-11, 15 foot |
| PC-15 |
400310M |
No |
3
conductor, Bantam to 310 plug, 12 foot |
| KS20908
L2 |
WECO |
No |
Test