ATS Series Craft Test Sets (Butt Sets) Instruction Manual
Click here to view this item in our Products section.
See how the Aines ATS-98 and ATS-2000 Telephone Test Set's compare to other test sets.
Pad Description
(Active Talk Not Available)
The TT Pad on the ATS Series Butt Sets is for featrure selection and dialing. This features are controlled by the top buttons, and the number pad is used for dialing. reading from left to right:
A. LNR Last Number Redial.
B. STO Store (dialed number).
C. ATLK* Active Talk for dry pair
    communication.
D. T/P Tone or Pulse dialing.
E. PSE Pause (dialing).
F. RCL Recall (stored number).
G. AMP* Receiver Amplifier.
H. FLSH Flash-hook Operation.
LNR
Depress to redial last number dialed.
STO
Used to store a commonly used number. Up to 10 numbers, 18 digits in length can be stored. To STORE a number connect the a live circuit, place the butt set in the TALK mode, press STO, dial the number, press STO, and then depress the number location (0 to 9) where you wish to store the dialed number. The stored number will remain until overwritten by another stored number. Pauses may be inserted into the stored number by depressing the PSE button. (Example: PBX-type dialing requiring a "9" to access an outside line before dialing.
1. Press STO.
2. Press 9.
3. Press PSE (Give long pause to allow dial tone to be present for an outside line.)
4. Dial "1-800-526-2463" (800-526-AINES)
5. Press STO
6. Press "I"
You have stored "9"..pause 1-800-2463 in the storage location.
ATLK*: Available on ATS-2000 Series ONLY. Used to allow conversations between two butt sets
over 3 spare (dead) pair. To activate, place butt set in TALK mode, and press ATLK. This activates
the feature. When the butt set is returned to MON mode, the feature is deactivated automatically.
T/P: Used to select Dual Tone Multi-frequency (DTMF) or Dial Pulse (DP) method of dialing. DTMF
dialing may be selected after DP dialing is completed to allow feature access requiring DTMF input.
PSE: Used to "inject" a pause in dialing when storing numbers (See STD above).
AMP*: Available on ATS-2000 Series ONLY. Receiver amplifier. Press to run receiver "ON" or "OFF".
Amplifier VOLUME controlled by the VOL button on the butt set grip.
FLSH: Provides automatic FLASH-HOOK (break in talk battery) to activate CLASS FEATURES
(call waiting, etc.).
The ATS Series of Butt Sets also provides features access on the set grip.
VOL: Reciever Amplifier volume control. Press button to switch between LOW and HI gain
(ATS-2000 ONLY).
MUTE: Mutes (shuts off) transmitter.
GND: Provides GROUND START (GS) function. To activate, place test leads on TIP and RING
of circuit under.
START: Test. Check POL light (LED) to correct polarity. Touch butt set belt clip to GROUND and
depress GS button. Circuit will activate and dial tone will be heard in the receiver. Relaese GS
button and remove belt clip from ground.
On the left side of the butt set.
TALK: Active or "OFF-HOOK" circuit condition.
MON: Monitor or "OFF-HOOK" circuit condition.
LED's: Circuit condition indicators (Light Emitting Diodes) are provided to check polarity of the butt
set connection and indicate the activation of the receiver amplifier. these LED's are located on the
hand grip above the VOL, MUTE, and GS buttons.
REV: (RED) Indicates the test leads are connected in reverse. Change before continuing tests.
NORM: (GREEN) Indicates test leads are correctly connected for testing.
REC: (YELLOW) Indicates Reciever Amplifier is actibvated (ATS-2000 Series ONLY).
Features requiring no activation (ALL sets):
Ringing: All Aines Series Butt Sets are provided with a patented auto-ring detection ciruit. This
circuit is active whenever the butt set is in the TALK mode. It is only activated when RINGING is
actually present on the line. It will automatically deactivate when ringing is stopped. This feature
allows the butt set to stay at "Hi-impedance" unless ringing is present.
Data: All ATS Series Butt Sets are data circuit activation "safe" while the butt set is in the
MONITOR (MON) mode. If the set is placed in the TALK mode, data circuit protection is NOT
PROVIDED (except for the ATS-2000 PLUS).
ATS-2000 PLUS: Data circuit activation safety in the TALK mode is provided on the ATS-2000
PLUS. Protection is provided as follows:
When a data circuit is encountered, a loud tone will be sounded in the receiver for five (5) seconds.
This allows the technician to disconnect from the circuit. If circuit interruption is desired, simply stay
on the circuit. Activation (interruption) will occur after five seconds.
CAUTION: IF YOU DO NOT WISH TO "TRIP" THE CIRCUIT UNDER THE TEST, DISCONNECT
WHEN TONE IS HEARD IMMEDIATELY! (YOU HAVE 5 SECONDS TO DISCONNECT.)
Maintenance:
No field maintenance of the Aines ATS Series is required except for battery replacement. The battery
compartment is accessible by removing two screws, one below the DTMF pad and one under the belt
clip. This also allows for field replacement of the butt set cords. The unit will retain it's stored number
memory for approximately 30 seconds while the battery is removed. A low battery status is indicated
by the unit defaulting to PULSE mode during periods of inactivity.
WARRANTY
All ATS Series Butt Sets are warranted for a period of ONE YEAR from date of purcahse.
Please refer to WARRANTY CERTIFICATE or call 1-800-526-AINES (1-800-526-2463) for details.
Copyright 1998 by Aines Manufacturing Corporation, Ronkonkoma NY 11779
Phone: 1-800-526-2463 - Fax: 1-631-471-3625
Site designed by PW Designs (516) 456-8358 pwdesigns411@yahoo.com