| ATS
Series Craft Test Sets (Butt
Sets)
Instruction Manual |
| Click
here to view this item in our Products section. |
| See
how the Aines ATS-98 and ATS-2000 Telephone Test
Set's compare to other test sets. |
| Pad
Description |
| (Active
Talk Not Available) |
| The
TT Pad on the ATS Series Butt Sets
is for featrure selection and dialing.
This features are controlled by the
top buttons, and the number pad is
used for dialing. reading from left
to right: |
 |
| A. |
LNR |
Last
Number Redial. |
| B. |
STO |
Store
(dialed number). |
| C. |
ATLK* |
Active
Talk for dry pair |
| |
|
communication. |
| D. |
T/P |
Tone
or Pulse dialing. |
| E. |
PSE |
Pause
(dialing). |
| F. |
RCL |
Recall
(stored number). |
| G. |
AMP* |
Receiver
Amplifier. |
| H. |
FLSH |
Flash-hook
Operation. |
|
| LNR |
| Depress
to redial last number dialed. |
| STO |
| Used
to store a commonly used number. Up
to 10 numbers, 18 digits in length
can be stored. To STORE a number connect
the a live circuit, place the butt
set in the TALK mode, press STO, dial
the number, press STO, and then depress
the number location (0 to 9) where
you wish to store the dialed number.
The stored number will remain until
overwritten by another stored number.
Pauses may be inserted into the stored
number by depressing the PSE button.
(Example: PBX-type dialing requiring
a "9" to access an outside
line before dialing. |
|
 |
|
| 1. |
Press
STO. |
| 2. |
Press
9. |
| 3. |
Press
PSE (Give long pause to allow dial tone
to be present
for an outside line.) |
| 4. |
Dial
"1-800-526-2463" (800-526-AINES) |
| 5. |
Press
STO |
| 6. |
Press
"I" |
|
| You
have stored "9"..pause 1-800-2463
in the
storage location. |
|
| ATLK*:
Available on ATS-2000 Series ONLY. Used to
allow conversations between two butt sets |
| over
3 spare (dead) pair. To activate, place butt set
in TALK mode, and press ATLK. This activates |
|
the feature. When the butt set is returned to
MON mode, the feature is deactivated automatically. |
| T/P:
Used to select Dual Tone Multi-frequency (DTMF)
or Dial Pulse (DP) method of dialing. DTMF |
|
dialing may be selected after DP dialing is completed
to allow feature access requiring DTMF input. |
| PSE:
Used to "inject" a pause in dialing
when storing numbers (See STD above). |
| AMP*:
Available on ATS-2000 Series ONLY. Receiver
amplifier. Press to run receiver "ON"
or "OFF". |
| Amplifier
VOLUME controlled by the VOL button on the butt
set grip. |
| FLSH:
Provides automatic FLASH-HOOK (break in talk
battery) to activate CLASS FEATURES |
| (call
waiting, etc.). |
| The
ATS Series of Butt Sets also provides features
access on the set grip. |
| VOL:
Reciever Amplifier volume control. Press button
to switch between LOW and HI gain |
| (ATS-2000
ONLY). |
| MUTE:
Mutes (shuts off) transmitter. |
| GND:
Provides GROUND START (GS) function. To activate,
place test leads on TIP and RING |
| of
circuit under. |
| START:
Test. Check POL light (LED) to correct polarity.
Touch butt set belt clip to GROUND and |
| depress
GS button. Circuit will activate and dial tone
will be heard in the receiver. Relaese GS |
| button
and remove belt clip from ground. |
| On
the left side of the butt set. |
| TALK:
Active or "OFF-HOOK" circuit condition. |
| MON:
Monitor or "OFF-HOOK" circuit condition. |
| LED's:
Circuit condition indicators (Light Emitting
Diodes) are provided to check polarity of the
butt |
| set
connection and indicate the activation of the
receiver amplifier. these LED's are located on
the |
| hand
grip above the VOL, MUTE, and GS buttons. |
| REV:
(RED) Indicates
the test leads are connected in reverse. Change
before continuing tests. |
| NORM:
(GREEN) Indicates
test leads are correctly connected for testing. |
| REC:
(YELLOW) Indicates Reciever Amplifier is
actibvated (ATS-2000 Series ONLY). |
| Features
requiring no activation (ALL sets): |
| Ringing:
All Aines Series Butt Sets are provided with a
patented auto-ring detection ciruit. This |
| circuit
is active whenever the butt set is in the TALK
mode. It is only activated when RINGING is |
| actually
present on the line. It will automatically deactivate
when ringing is stopped. This feature |
| allows
the butt set to stay at "Hi-impedance"
unless ringing is present. |
| Data:
All ATS Series Butt Sets are data circuit activation
"safe" while the butt set is in the
|
| MONITOR
(MON) mode. If the set is placed in the TALK mode,
data circuit protection is NOT |
| PROVIDED
(except for the ATS-2000 PLUS). |
| ATS-2000
PLUS: Data circuit activation safety in the
TALK mode is provided on the ATS-2000 |
| PLUS.
Protection is provided as follows: |
| When
a data circuit is encountered, a loud tone will
be sounded in the receiver for five (5) seconds.
|
| This
allows the technician to disconnect from the circuit.
If circuit interruption is desired, simply
stay |
| on
the circuit. Activation (interruption) will occur
after five seconds. |
| CAUTION:
IF YOU DO NOT WISH TO "TRIP" THE CIRCUIT
UNDER THE TEST, DISCONNECT |
| WHEN
TONE IS HEARD IMMEDIATELY! (YOU HAVE 5 SECONDS
TO DISCONNECT.) |
| Maintenance: |
| No
field maintenance of the Aines ATS Series is required
except for battery replacement. The battery |
| compartment
is accessible by removing two screws, one below
the DTMF pad and one under the belt |
| clip.
This also allows for field replacement of the
butt set cords. The unit will retain it's stored
number |
| memory
for approximately 30 seconds while the battery
is removed. A low battery status is indicated
|
| by
the unit defaulting to PULSE mode during periods
of inactivity. |
| WARRANTY |
| All
ATS Series Butt Sets are warranted for a period
of ONE YEAR from date of purcahse. |
| Please
refer to WARRANTY CERTIFICATE or call 1-800-526-AINES
(1-800-526-2463) for details. |